Aqua Cooler WM5SS 사용 및 관리 매뉴얼 - 페이지 6

{카테고리_이름} Aqua Cooler WM5SS에 대한 사용 및 관리 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Aqua Cooler WM5SS 13 페이지. Wm series

REMOVING FROM SERVICE

1.
Disconnect the power supply cord.
2.
Disconnect the water supply.
3.
Remove drain assembly from rear of the fountain.
4.
Remove bubbler valve and if present, glass filler.
5.
Always drain all water when freezing temperatures are anticipated and before shipping the fountain.

MAINTENANCE

The only maintenance operation required is the removal of dirt and lint from the condenser. Inspection
should be made at 3 month intervals.
1.
Disconnect the power supply.
2.
Clean the condenser with a small stiff non-wire brush.
The unit is equipped with a hermetically sealed compressor and requires no additional lubrication.
The fan motor on this unit seldom needs oiling. If required, a few drops of SAE 10 oil should be used.
Aqua Cooler recommends the water fountain is cleaned every month, ensuring there is no blockage in the
condenser or in the back of the unit. Please remove all potentially harmful factors to prevent any scratch or
damage to the unit.
If customers require the unit's spare parts information, please contact the Aqua Cooler Service Department
for further assistance. The direct line is located on the back of this manual.

TROUBLESHOOTING

Problem
No water flowing out of the
glass filler or bubbler
Water is not cold
Your Partner in Cool.
6
Possible Cause
Water source has been suspended
The filtration system is clogged
The cooling controller is turned off
Power failure
Cooling system failure
Remedy
Restore water supply.
Replace the filter.
Check the position of the mechanical thermostat
and set to desired temperature.
Check the power cord is properly plugged in or if
there is a power outage.
Turn off the fountain and contact Aqua Cooler
service.