A.H. Systems SAS-550-1B 사용자 설명서 - 페이지 8

{카테고리_이름} A.H. Systems SAS-550-1B에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. A.H. Systems SAS-550-1B 14 페이지. Antenna kit
A.H. Systems SAS-550-1B에 대해서도 마찬가지입니다: 운영 매뉴얼 (13 페이지), 운영 매뉴얼 (9 페이지)

A.H. Systems SAS-550-1B 사용자 설명서
A.H. Systems Model Active Monopole Antennas

CALIBRATION

Equivalent Capacitance
With changes to our Active monopole antenna (converting the input connection from a BNC to a
more rugged ¼-20 input) our element diameter changed to 6.17mm (Average). It is our
recommendation to use a 12 pF for the ECSM fixture for an element height of 41" (1.04 meter) as
per ANSI C63.5:2017 and CISPR 16-1-6:2017.
The formula for calculating the capacitance is (per ANSI C63.5:2017 and CISPR 16-1-6:2017):
where:
h = actual length of the monopole element (adjusted to 1.04m), m
a = average radius of the antenna element (6.17mm), m
λ = wavelength in meters
C
= capacitance of the dummy load
a
NOTE - Other fixtures with different capacitance are available as an option.
Effective Height Calculation
The correction factor for the calibration is dependent on the height of the monopole. The effective
height is calculation is:
where:
λ = wavelength in meters
h = Telescoping element height in meters
Examples:
For a 41" (1.04 Meter) length, the effective height would be 0.52 meters (up to approximately
2 MHz) and the correction factor should be 20*Log(0.52) = -5.68 dB.
For a 1 Meter length, the effective height would be 0.5 meters (up to approximately 2 MHz)
and the correction factor should be 20*Log(0.5) = -6.02 dB.
© A.H. Systems inc
REV E
= (55.6 h) / (ln(h / a) – 1) * (tan(2 π h /λ)) / (2 π h /λ)
C
a
(λ/ 2π) * tan(2 π h /λ)
h
e =
Eq 1
Eq. 2
8