ADA REQUIREMENTS:
The Ranger 2 Pool Lift is ADA Compliant.
The installation must meet the following requirements:
•
Clear deck space dimensions (see FIGURE 1)
•
Lift installed between 14.5-19 inches from the pool edge
•
Deck slope no greater than 1:48
•
The seat must submerge at least 18 inches into the water. The lift should be
installed at a location with 42-48 inches of depth (deck to pool fl oor)
•
Anchor setbacks are based on straight pool/spa walls. Curved pool/
spa walls will eff ect the anchor setback.
36"
30.5"
16"
MIN
Copyright © 2019 Aqua Creek Products All Rights Reserved
Installation: ADA Guidelines
ADA REQUIRED
CLEAR DECK SPACE
(36" X 48")
FIGURE 1
49.5"
48"
12"
13"
**NOTE: THE MAXIMUM
POOL WALL
11"
**14.5"
SETBACK IS 19"
Revised 6/17/19
4