A.J.Antunes 9210826 매뉴얼 - 페이지 8

{카테고리_이름} A.J.Antunes 9210826에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. A.J.Antunes 9210826 20 페이지. Club toaster

CLUB TOASTER CTX-200L
PLTN
Light
PLTN
MOTOR
ADJUST
PRGM
CT
BELTS
STOP/START
Figure 6. Adjusting Toasting Quality

Viewing the Program Mode Settings

Follow these steps to view these settings:
1. From the Ready or Wait modes, press and hold
the PRGM button for 3 seconds.
2. The following appears on the display:
Program Club
Press Select
3. If desired, use the NEXT or PREV button to scroll
through the following categories:
• Speed
• Units (F/C) (default setting is F)
• Top Temp
• Bottom Temp
4. When the desired category is reached, press
the SELECT button ONCE. This will cause the
selected category value to blink indicating it is in
edit mode.
NOTE: The current setting will be the FIRST setting
shown in the display.
5. Press the PREV or NEXT buttons while the value
is blinking to change adjust the setting.
Note: Do NOT change any of these settings for ANY
reason! For assistance in changing these options,
please call the factory.
6. When you are finished viewing settings, press the
PRGM button to return to the Ready screen or
wait 10 seconds until the Ready screen appears.
NOTE: The unit will exit the Program Mode after 10
seconds of inactivity.
OPERATION (continued)
Buns
Dark
PREV
NEXT
SELECT
Club Toaster Settings
The following table describes the recommended Club
Toaster operating settings.
Setting
Bottom Temp. (Lower
Platen)
Top Temp (Upper Platen)
Speed (22 seconds)
NOTE: If you wish to change any of the above set-
tings, contact the factory for instructions.

CT Unit Status Mode

This mode provides feedback on unit performance. No
adjustments can be made in this mode. Also, the dis-
play remains on the selected screen in this mode until
you switch screens or exit the Unit Status mode.
Follow these steps to view the Unit Status mode:
1. From any operation mode (Ready or Wait) press
and hold the ADJUST button for 3 seconds.
2. The following appears on the display in sequence:
Speed-Motor-Set Pt
Total Hours
Controls Temp (Air temperature inside the
electrical enclosure)
Top Temp (Actual temperature and set point
temperature)
Bottom Temp (Actual temperature and set
point temperature)
Smart Kitchen
Network Not Detected
8
Value
570°F (299°C)
570°F (299°C)
1700
P/N 1010993 Rev. H 03/15