Problem
The unit displays the following mes-
sage:
Upper Sensor Fail
Lower Sensor Fail
Note: A thermocouple which has
become grounded will cause erratic
controller behavior
The overtemp thermocouple tempera-
ture is greater than 250ºF (121ºC) but
less than 350ºF (176ºC).
The overtemp thermocouple tempera-
ture is greater than 350ºF or an open
thermocouple condition exists.
The unit is running too hot.
Unit displays the following message:
WARNING! Power Fault
Unplug now!!!
P/N 1011038 06/09
McDonald's
troublesHootING (continued)
Possible Cause
The Thermocouple in the Platen
circuit has failed.
A control relay has a short or the
Thermocouple is not pushed into the
Platen correctly.
There is a problem with the main
convection blower.
There is a problem with the main
convection blower.
Cooling Fan failure.
Contactor and control relay failures.
Unit has detected IR current or rising
Platen temperature with the power
off.
15
Club ToasTer CTX-200l
Corrective action
The toaster cannot be operated
with this type of failure. Contact
your Authorized Service Agency for
service.
The toaster will open the C1
contactor, disabling the toaster.
Contact your Authorized Service
Agency for service.
The toaster will shut down. Allow
the toaster to cool down and
restart. If this condition persists,
contact your Authorized Service
Agency for service.
The toaster will shut down. Allow
the toaster to cool and then restart.
If this condition persists, contact
your Authorized Service Agency for
service.
The toaster will operate normally
until the compartment ambient
temperature exceeds 160ºF (71ºC).
At this point, the toaster will shut
down. Contact your Authorized
Service Agency for service.
Immediately unplug the power cord
and call your Authorized Service
Agency for service. The unit must
not be operated with this kind of
failure.