11. TROUBLESHOOTING
In case the energizer is not working properly, try to solve it according to the following table.
Cause
Energizer does not work?
Red blinking on the LED control
Lead-in or short circuit of supply lines of the fence
system.
Conductor has adverse properties (thin diameter,
high resistance).
Low-quality earthing, too short earth rod,
corrosion, dry soil.
Lead-in via growth near fence system.
Conductor on ground (for example break,
insufficient mechanical tension).
Too long fence system. Was correct accessories
used for given purpose?
Insulator pierces, losses occur.
Conductor is connected via knot, insufficient
connection.
14
Fault removal
The energizer is either manuály switched off, then
switched on. If it cannot be switched on, then
disconnect it from the fence systém, plug it into the
mains using an adapter and then switch the energizer
again. If the blue or purple LED is on, then the device
is fine. I fit is red, then the points see below. Otherwise,
the device is damaged (contact the seller) During using
battery and battery operated devices, observe the
correct connection of the poles.
The voltage on the fence has dropped below 3 kV - it
is necessary to check the fence and remove all voltage
leaks (growth, bad insulators,...)
Do not use conventional cables for supply lines.
Highvoltage cable is recommended.
Use high-quality conductor with low resistance and
larger diameter. Ensure high-quality correct connection
of conductors.
Add next rod, moisten.
Remove the growth (mow it).
Repair fencing, use special connectors, stretch
conductor.
Use accessories suitable for given length of fence
system and for animals – in case of need, consult
specialized salesman.
Replace defective and weather-worn insulators.
Use relevant special connectors for the conductor.