Aqua Exclusive DRUM FILTER C-25 EVO 소유자 매뉴얼 - 페이지 18

{카테고리_이름} Aqua Exclusive DRUM FILTER C-25 EVO에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Aqua Exclusive DRUM FILTER C-25 EVO 20 페이지.

Aqua Exclusive

Maintenance

Maintenance & Disassembly
The device requires maintenance at least once a month. During maintenance the power sup-
ply must be disconnected. The screen panel should be checked for wear and tear.
1. Disconnect the power supply and close the piping.
2. Ensure that the water can drain out of the housing.
3. Turn the entire drum one revolution by hand and check the assembly for wear. If neces-
sary, you can replace the screen panel (see the next page).
4. Also check the drain for any filamentous algae/dirt that may have collected.
5. Place the lid back on the housing and put the plug back in the socket.
Activation Of 'Drum Filter' Bypass:
During a treatment or in the event of a problem the drum can be short-circuited by means of
the bypass.
Activation Of Bypass:
1. Switch off control box.
2. Remove two red caps from the partition wall.
3. Connect circulation pump to 110V mains outlet
Setting Slip Clutch Torque 65nm
The drive shaft is fitted with a slip clutch that allows the shaft to turn freely if something pre-
vents the drum from turning.
Setting Torque:
1. Remove motor cover.
2. Place torque spanner on M10 nut on the shaft.
3. Prevent drum from turning and torque to 65nm.
16
C-25 EVO OWNER'S MANUAL