AB Quality SD3000 PLUS 설치 지침 매뉴얼 - 페이지 5
{카테고리_이름} AB Quality SD3000 PLUS에 대한 설치 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. AB Quality SD3000 PLUS 12 페이지. Dc drive regulator
4
SD3000 PLUS DC Drive Regulator
Connecting Power Wiring
and Grounding
No. Name
Input Power
1
Terminal Block
L1, L2, Ground
Ground Stud
2
External Gate
3
Power Supply
Meter Ports
4
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Engineered by
GP
P.M. FLT
LP
EXT. FLT
OK
COM OK
XMT
RCV
4
METER
PORTS
ARM
FDBK
3
FIELD
SD3000
Table 1.A Terminal Specifications
Part Number for Customer Plug
Description
(provided with SD3000 PLUS)
Input power
94809302
Chassis Ground
Use grounding cable kit 97297501 provided with regulator
External Gate
94809301
Power Supply
(if used)
Meter Port Output 49455-115H
FWD - GATES
FDBK OK
RPI
MCR
AUX IN 1
AUX IN 2
AUX IN 3
AUX IN 4
AUX IN 5
AUX OUT
REV - GATES
RESOLVER
FEEDBACK
DRIVE
I/O
FUSE TYPE
250VAC
120VAC
3AG 7A
EXT GATE P/S
L1
L2
PLUS
DRIVE CONTROL
Wire Size Range
Maximum
Minimum
2
4.0 mm
2.5 mm
(10 AWG)
(14 AWG)
10 AWG,
18 AWG,
Twisted Pair,
Twisted Pair,
2 Twists / in.
2 Twists / in.
14 AWG,
22 AWG,
Twisted Pair,
Twisted Pair,
2 Twists / in.
2 Twists / in.
13feet (4m)
13feet (4m)
max. length
max. length
1
2
Torque
Recommended
2
0.677909 N-m
(6 lb.-in.)
0.677909 N-m
(6 lb.-in.)
0.677909 N-m
(6 lb.-in.)