TroubleShooTinG

To avoid possible personal injury and/or damage to the unit, inspection, test, and repair of electrical equipment should be performed by qualified
service personnel. The unit should be unplugged when servicing, except when electrical tests are required. Use extreme care during electrical circuit
tests. Live circuits will be exposed. If the troubleshooting steps listed below do not solve your machine's problem, contact an Authorized Service
Agency for further assistance.
problem
Control Display is blank (power is on
but indicator light is off).
Control Display is blank (power is on
and indicator light is on).
Unit does not heat up (Control Display
is on).
The unit's main electrical panel
circuit breaker trips.
Water leaking inside electrical
housing.
"Err" appears in the Control Display.
P/N 1010881 Rev. F 03/12
WarNING
possible Cause
The power cord is not correctly plugged in.
The power cord and/or electrical plug is damaged.
The main electrical panel circuit breaker is off or has
been tripped.
Switch is inoperable.
Control Board is inoperable
Transformer is inoperable.
Loose, burnt, or broken wires in circuit.
Hi-Limit Thermostat is tripped or inoperable.
Solid State Relay is inoperable.
Thermocouple is inoperable.
Control Board is inoperable.
Steam Generator is inoperable.
Loose, burnt, or broken wires in circuit.
Damaged receptacle, plug, or cord; a loose connec-
tion; or an internal component failure.
Pinhole leak in rubber hoses
Loose or damaged water line tubes and/or fittings
inside electrical housing.
Programming and/or SHO and H2O values were
adjusted/changed improperly.
Plug the power cord into the appropriate outlet.
Inspect electrical wire, plug, and receptacle.
Reset circuit breaker. Contact your maintenance per-
son or Authorized Service Agency if it trips again.
Contact your maintenance person or Authorized
Service Agency for service.
Contact your maintenance person or Authorized
Service Agency for service.
Reset the Hi-Limit Thermostat according to the
Operations section of this manual. If the Hi-Limit
Thermostat requires continuous resetting, contact
your Authorized Service Agency for service.
Turn the power off, allow the unit to cool to room
temperature, and then restart the unit. Contact your
maintenance person or Authorized Service Agency if
the condition repeats.
Replace hoses.
Tighten or replace tubes and/or fittings.
Reset the Control Board as described in the
Programming section of this manual. See Fault
Codes.
9
Corrective action