AB Quality MobileView Guard G750 빠른 시작 매뉴얼 - 페이지 7

{카테고리_이름} AB Quality MobileView Guard G750에 대한 빠른 시작 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. AB Quality MobileView Guard G750 20 페이지.

Handling of MobileView Guard Terminal
Refer to MobileView Guard G750 User Manual for additional handling instructions
to avoid terminal malfunctions or damage.
Power Supply
ATTENTION
!
Enabling Switches
The electronic enabling switch realizes the enabling equipment as a safety function
for machines in special operating modes. The enabling switch is part of the
MobileView terminal.
Each machine features a normal operating mode and a special operating mode.
• In normal operating mode, guards and/or operative protection devices are
used to prevent access and guarantee safety. Special operating modes are
used to maintain the normal operating mode.
• The device meets safety class III in accordance with EN
61131-2 and EN 50178. The 24V power supply for the
equipment must provide appropriate isolation between
safety-extra-low-voltage circuits and dangerous-contact
voltage circuits (for example, by safety transformers or
similar facilities).
• Protect the power supply circuit with a 3.15 A fuse.
• The nominal supply voltage of the MobileView terminal
(without Mobile View Connection Cable) is +24V dc
(supply voltage range: 18 to 32V dc).
Typical current consumption is:
- 300 mA at 24V dc
-400 mA at 18V dc
When planning the power supply, consider the voltage
drop on the MobileView Connection Cable.
Specifications of power supply lines in this cable are:
Cross section: AWG24 (0.24 mm
Material: zinc-coated copper strand
Line resistance:
MobileView Guard G750
2
)
<
<
90 Ohm/km (
145 Ohm/mile)
Publication 2727-QS002E-MU-P
7