FIGURE 1
Clamp Nut
Clamp Bolt
Initial Startup
WARNING
Before Starting the Pump
1. Use ONLY original components. Non-original clamp
components may fail in use and cause explosive
component separation. Verify that upper and lower filter
bodies are properly secured with the filter body clamp.
Never rely on hand tightening the clamp nut to the clamp
bolt. Using a ¾" socket on a torque wrench, torque clamp
nut to clamp bolt to 150 inch-lbs. (See Figure 1) Verify that
the filter manual air relief body is in the LOCK position,
and no filter components are missing, damaged or not
genuine AquaGuard components. (See Figure 2)
2. Close filter drain.
NOTE: Filter plug requires an O-Ring seal (See Figure 4)
2. Open all system valves to allow water from the pool to the
filtration system and from the filter to return to the pool.
4. OPEN the manual air relief valve. (See Figure 2)
Starting Pump
1. When starting system pump, do not stand over/near filter.
If water leakage appears at filter tank clamp, immediately
turn off all system circulation pumps and all electrical
power. Do not return to the filter until all water leakage
has stopped. Reassemble the clamp system per the
instructions on page 7 in this owner's manual to stop leak.
2. Return to filter to CLOSE manual air relief valve only when
a steady stream of water (not air or, air and water mix) is
discharged from the manual air relief valve.
Filtering
Filtration starts as soon as flow is steady through the
filter. As the filter removes dirt from the pool water, the
accumulated dirt causes a resistance to flow. As a result, the
gauge pressure will rise and the flow will decrease. When
the pressure rises between 7 - 10 PSI above the starting
pressure, or when the flow decreases below the desired rate,
clean or replace the filter cartridge elements. Once your filter
is running and there is a pressure reading, line up the green
arrow with the current reading. (See Figure 3) When the
pressure rises to or above the red or second arrow, it is time
to clean or replace your filter cartridge elements.
FIGURE 2
Manual air relief shown open.
To Open
To Close
FIGURE 3
Time to
Clean
7-10 PSI
Filter Cartridge
Pressure Reaches
Red Arrow
Clean
Pressure
Place Green
Arrow Hear
0 PSI
By recording the initial starting pressure (with clean filter
elements) a determination can be made when the filter
cartridge elements should be replaced rather than cleaned.
After the filter elements have been cleaned and reinstalled if
the starting pressure is higher than 6 PSI above the starting
pressure with the new filter cartridge elements, the filter
cartridge elements should be replaced the next time the
gauge arrow reaches the red arrow.
Maintaining Your Filter
WARNING: Product should be
installed/serviced only by a
qualified pool professional.
Filter Disassembly Instructions
1. Turn off all system circulation pumps and all electric
power on the equipment pad.
2. Set all system valves to prevent water flow to the filter.
3. The manual air relief valve must be placed in the OPEN
position. (See Figure 2)
4. Remove filter drain plug (See Figure 4) and drain water
from filter.
5. Using ¾" wrenches or hex sockets, loosen and remove the
clamp nut and the clamp bolt. (See Figure 1)
6. Holding both ends of the filter clamp carefully spread the
clamp ends. Remove the clamp by lifting over the upper
filter body. Do not to drop the clamp during removal,
because the clamp could be damaged. Do not strike the
clamp with metal tools as they can damage the clamp.
7. Lift off upper filter body. Do not use the pressure gauge to
lift the upper filter body.
Filter Disassembly Instructions
1. Remove the top Manifold, which is exposed when the
upper filter body is removed. (See Figure 4)
2. Remove the filter cartridge elements by using slight
rocking motion and lifting up.
3. Clean filter cartridge elements
FIGURE 4
Manifold
Drain Plug
w/ O-Ring
Lower
Body
AquaGuard | MasterPro
5