DeZurik APCO CVS-6000 설치, 운영 및 유지보수 매뉴얼 - 페이지 7
{카테고리_이름} DeZurik APCO CVS-6000에 대한 설치, 운영 및 유지보수 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. DeZurik APCO CVS-6000 11 페이지. Swing check valves
DeZurik APCO CVS-6000에 대해서도 마찬가지입니다: 설치, 운영 및 유지보수 매뉴얼 (19 페이지)
APCO CVS-6000 Convertible Swing Check Valves
Operation
The CVS-6000 Convertible Swing Check Valve prevents back flow of the media on pump shut down or
power failure. It offers unobstructed flow through area. This advantage is accomplished in design by
locating the pivot point of the disc well outside its periphery, thus it is possible for the entire disc to lift
clear of the flow area. This is a very desirable feature when pumping raw sewage.
As service requirements change, the CVS-6000 Convertible Swing Check Valve can be converted to
any of the following models:
1.
CVS-6000-AC – Cushioned Swing Check Valve Air Cushioned Side Mounted
2.
CVS-6000-BMB – Cushioned Swing Check Valve Oil Control Bottom Buffer
3.
CVS-6000-OC – Cushioned Swing Check Valve Oil Control Side Mounted
Note: Kits for any of the above conversions can be supplied for field installation.
Be aware that the Convertible Swing Check Valve is not a silent closing check valve.
December 2012
Page 7
DeZURIK
D12009