Hi / Low refrigerant pressure cutout switch
For models DSHP-7, 8, 9 & 10 there is a pressure switch serves both as a high and low refrigerant safety
cutout to protect the heat pump. If there is no air or low air flow through the condenser the pressure
will build-up and cause the switch to trip off. When there a refrigerant leak, the switch will protect the
heat pump from functioning.
To reset the switch:
1. Remove black heat pump cover and locate
the Hi / Low pressure cutout.
2. Press the brass button to reset the heat
pump.
If the pressure switch will not reset call
Aqua Logic for help.
Copyright© 2016 Aqua Logic, Inc. Effective date of 1/2016