Replace Bulb:

WARNING: Be sure to wear protective gloves and goggles!!
Remove power from UV sterilizer
Turn off pump.
Remove screws from UV lid and remove the lid.
Carefully lift UV bulb from top of chamber.
Pull bulb pin connectors from bulb as shown in bottom-right picture
and then lift pull bulb from quartz sleeve.
Replace bulb. We recommend using a clean oil-free cloth to protect
bulb from skin oils.
Attach bulb pin connectors to the bulb as shown in top-right picture.
Push connector down on bulb until it snaps on bulb as shown in the
picture.
Carefully slide bulb into chamber.
Replace UV sterilizer lid and install screws.
Turn on pump.
Apply power to UV Sterilizer
The view port should show a blue light after a few seconds.
Replacing the quartz sleeve:
WARNING: Be sure to wear protective gloves and goggles!!
Unplug or remove power from UV sterilizer.
Remove screws from UV lid and remove the lid.
Carefully lift UV bulb from top of chamber. Pull bulb pin connectors from bulb as shown in bottom-
right picture and then lift bulb from quartz sleeve.
Carefully use a pair of channel-lock pliers or wrench to turn 2" nuts counter-clockwise on top and
bottom of chamber.
Remove "O" rings.
Slide quartz-sleeve assembly out of chamber.
Slide new quartz-sleeve assembly into chamber. We recommend using a clean oil-free cloth to
protect bulb from skin oils.
Install "O" rings.
Carefully tighten quartz compression nuts with channel-lock pliers or wrench.
Replace bulb. We recommend using a clean oil-free cloth to protect bulb from skin oils.
Attach bulb connectors at an angle to bulb as shown in top-left picture.
Push bulb pin connectors down on bulb as shown in top-right picture.
Carefully slide bulb into quartz-sleeve assembly.
Inspect UV sterilizer for leaks around the top of the chamber.
Replace UV sterilizer lid and install screws.
Plug in or apply power to the UV sterilizer.
The view port should show a blue light after a few seconds.