DeZurik G-SERIES 매뉴얼 - 페이지 8

{카테고리_이름} DeZurik G-SERIES에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. DeZurik G-SERIES 12 페이지. Lift, turn and reseat used on ptw & pfw tapered plug valves
DeZurik G-SERIES에 대해서도 마찬가지입니다: 지침 (7 페이지), 매뉴얼 (8 페이지), 매뉴얼 (17 페이지), 매뉴얼 (14 페이지), 매뉴얼 (14 페이지), 매뉴얼 (16 페이지), 지침 (19 페이지), 매뉴얼 (17 페이지), 사용 설명서 (13 페이지), 매뉴얼 (9 페이지)

DeZurik G-SERIES 매뉴얼
DeZURIK
Cylinder Operated G-Series Actuator
Disassembling Actuator
7. Mark the teeth of the rack and gear as shown in
Figure 3 and lift the gear sector out of the actuator;
be careful not to lose the actuator drive key.
8. Remove the nuts from the end of the rack rod.
9. Remove the screws or nuts fastening the cylinder
assembly to the housing and carefully remove the
cylinder assembly by sliding it away from the
actuator until the rack rod clears the actuator
housing.
10. Remove the rack from the housing.
11. Remove the rack bearing (if noticeable wear to
bearing) by prying it from the actuator housing.
12. Scribe corresponding lines on the valve and
adapter to be used for alignment during actuator reassembly.
13. Remove the screws fastening the adapter to the valve, and then lift the actuator and adaptor off
the valve.
14. Lift the rest of the actuator and the adapter off the valve.

Reassembling Actuator

Install new bearings and seals in the adapter and cover if necessary. See Figure 4 for proper
placement.
D10082
(Continued)
Figure 4 – Location of Actuator Seals and Bearings
Page 8
Figure 3 – Scribe Marks
October 2012