DeZurik POWERRAC R3 설치 및 운영 매뉴얼 - 페이지 10

{카테고리_이름} DeZurik POWERRAC R3에 대한 설치 및 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. DeZurik POWERRAC R3 15 페이지. Cylinder actuator

DeZURIK
R3 PowerRac

Mounting Actuator on Valve

Refer to Figures 1 and 2 for component identification.
1.
Select one of the available actuator-to-valve mounting positions shown on the Installation
Drawing. Match the open or closed position of the valve with the open or closed position of
the actuator. Also, note the position of the word "open" on the top cover (B11). The cover must
be positioned on the housing (B1) so that dial hash mark for "open" will be parallel with the
pipeline when the valve is installed. One or more of the following four steps may be required,
depending upon the positions of the valve, the actuator, the actuator cover, and the mounting
position selected.
a. Rotate the valve shaft, and/or
b. Stroke the actuator, and/or
c. Select a different actuator-to-valve mounting position, and/or
d. Remove and re-index the cover. If this step is necessary, remove the four cover screws
B15), rotate the cover, and replace the four cover screws (B15) and washers (B14).
Tighten the screws to 15 ± 2 foot pounds (20 ± 3 Nm).
2.
If the actuator does not include the collet assembly (the components are identified in Figure 1,
grease the components as described in the Actuator Reassembly section and install the
assembly as explained in steps 17 and 18 in the same section.
D10359
Cylinder Actuator
TM
Figure 3 – Collet Assembly
Page 10
August 2016