RE-ASSEMBLY PROCEDURE
1.
If the exhaust valve has been removed, pass the valve
tail through the hole in the casing from the outside and
pull gently until the notch is inside the casing. If it is a
new valve cut off any excess tail leaving about 5mm.
2. Fit a new O-ring (7) into the groove on the venturi knob
(6) and in the groove on the crown holder (22).
3. Fit the O-ring (20) onto the seat (21)
4. Insert the seat(21) into
the crown holder (22).
Use tool 125727 to screw
the seat fully home
against the crown holder.
Service manual Calypso second stage
5. Fit a new seat into the crown holder.
7. Fit the seat into the crown holder. This is to avoid
damaging the new crown. Screw the crown holder assembly
onto the insert (15) fitted with the poppet.
.
6. Fit a new square
poppet (16) using the
crown holder (18); then fit
the spring (17) into the
insert (15), then the
poppet (18).
8. Fit the lever (14).
The lever should be
opposite the injection
hole.