Aqua Lung Legend LX Second Stage 기술 유지보수 매뉴얼 - 페이지 6

{카테고리_이름} Aqua Lung Legend LX Second Stage에 대한 기술 유지보수 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Aqua Lung Legend LX Second Stage 18 페이지.

Aqua Lung Legend LX Second Stage 기술 유지보수 매뉴얼
6
12.
Remove the o-ring (22)
from the valve body.
13.
Insert a small 1/8" wooden dowel into the threaded end
of the valve body and push out the shuttle valve as-
sembly (26-30). Separate the shuttle valve assembly by
pulling on each end.
14.
Using a fingernail, remove the LP seat (26) and small
o-ring (28) from the shuttle valve.
15.
Using a medium blade screwdriver, turn the crown (21)
six to seven full turns counterclockwise. Since the crown
is o-ring sealed, it will not completely unscrew from the
valve body. Insert the pin end of the seat extractor tool
(pn 109436) into the valve body, grasp the pin and pull
the crown completely out of the valve body. Remove the
o-ring (20) from the crown.
Legend LX Second Stage Service Manual
16.
To remove the exhaust
tee (14), submerge the
box bottom with tee in
hot water (approximately
125°F) for 2 to 3 minutes.
Grasp the tee by one of
its wings and pull it off
the box bottom.
17.
Fold back the edges of
the exhaust valve (13) and
inspect underneath. The
seating surface should be
clean and free of damage.
Inspect the exhaust valve.
It should be supple and
have well defined edges.
If it looks good, there is no
need to remove it and it may be reused. If there is any
sign of deterioration, it should be replaced.
18.
If you have a Legend LX
Supreme, remove the lip
shield (11). To remove the
mouthpiece clamp (10),
simply lift the lever on the
cam latch. Remove the
mouthpiece (12).
This Ends Disassembly
Before starting reassembly, perform parts
cleaning and lubrication according to the
procedures outlined in Procedure A, titled
Cleaning & Lubrication, on page 15.