Mistral Second Stage Technical Maintenance Manual
Properly position the face of the adjusting tool (p/n 125727) on the
top of the sealing ring (4). Using a ¼" nut driver, tighten or loosen
the locknut to adjust the lever height so that the lever is touching
the tool. To raise the lever height, tighten the locknut in until the
lever reaches the correct height. To lower the lever height, loosen
the locknut. With the lever touching the tool, there should be
no leaks.
CAUTION:
1. The adjusting tool must be used
in the right direction, with the cut out in the
center of the tool facing up.
2. The tool should be placed in line with the
inlet fi tting (19) (see photos).
Once the adjustment is completed, turn off the air supply and
purge the regulator.
19. Install the sealing ring (4) onto the diaphragm (5) and
place the assembly into the inhalation box (6).
20. Place the exhalation box (2) onto the inhalation box (6),
then install the 4 screws (1).
21. Fit 4 new locknuts (7) into the inhalation box, then tighten
the screws (1) using a 3 mm allen key until snug.
22. Tighten the MP hose to the second stage using a 11/16
(17mm) crow's foot, apply a torque of 40 in/lbs.
NOTE:
The original Mistral regulator used
Panduit clamps to attach the corrugated hoses
to the mouthpiece and second stage. New
re-usable clamping bands are now being
used. they have been added to the service
kit for a period of two years. these should be
installed during annual service.
23. Install the cleaned corrugated hoses to the inhalation/
exhalation boxes and the mouthpiece. Do not install the
clamping bands in this step.
NOTE:
Cleaning procedures for the corrugated
hoses are found on p. 14, Procedure A:
Cleaning and Lubricating.
a. The "M" clamping band will be used on the mouth-
piece. For detailed installation prodecures, see the Mistral
Mouthpiece Technical Maintenance Manual.
CAUTION:
The corrugated hoses should be fi tted
to the connectors so that the gas can circulate in
the direction indicated by the arrows engraved on
the mouthpiece body.