Aqua Lung Octopus 기술 게시판 - 페이지 4

{카테고리_이름} Aqua Lung Octopus에 대한 기술 게시판을 온라인으로 검색하거나 PDF를 다운로드하세요. Aqua Lung Octopus 4 페이지. Second stage
Aqua Lung Octopus에 대해서도 마찬가지입니다: 유지 관리 매뉴얼 (20 페이지)

Aqua Lung Octopus 기술 게시판
Aqua Lung America
18
Fit the diaphragm washer (2) evenly into the front of the dia-
phragm (3). Place the assembly into the case (5).
19
Fit the front cover (1)
onto the front of the case
(5) pulling the retaining loop
over the venturi knob (17). Visu-
ally inspect the cover to confirm
that it is seated evenly all the
way around.
NOTE:
If your facility is equipped with a test bench, perform the tests
before installing the mouthpiece. General instructions for performing
bench tests are located in the Technical Maintenance Manual.