Aqua Lung America
18
Fit the diaphragm washer (2) evenly into the front of the dia-
phragm (3). Place the assembly into the case (5).
19
Fit the front cover (1)
onto the front of the case
(5) pulling the retaining loop
over the venturi knob (17). Visu-
ally inspect the cover to confirm
that it is seated evenly all the
way around.
NOTE:
If your facility is equipped with a test bench, perform the tests
before installing the mouthpiece. General instructions for performing
bench tests are located in the Technical Maintenance Manual.