- Masonry walls (MW). Leave 50mm between the stove and walls what provided that the air can
circulate in front and to one side of the stove.
If the stove is installed into a recess made of non-flammable material (stone, concrete), then the
distance between the wall and the stove must be at least 50 mm, to allow for proper air movement.
There must be no electrical equipment or cables within the safety zone of the sauna stove.
2.4. Connecting the sauna stove to the smoke flue
As a rule, the „COZY" sauna stoves have the flue gas outlet opening on top of the sauna stove. Special
metal flue pipes must be used for connecting the sauna stove to the smoke flue; the flue pipe
connections must be sealed with heat-resistant sealing cord if necessary. Any bends in the connection
pipes must be round and wide, in order to ensure minimum obstructions of the chimney draught. The
flue pipe must enter through the chimney wall and it must be sealed with mineral wool. The connection
of the sauna stove to the smoke flue must be made by a specialist of the relevant field.
The sauna stove must not be modified without the manufacturer's consent.
TW (THROUGH THE WALL)
2.5. Models COZY
Installing the Stove in an opening in a concrete or brick wall
The stove is installed in an opening in a concrete or brick wall. The minimum width of the opening is
COZY12 - 255 mm, COZY 18 - 315mm and the minimum height from the floor is COZY12 - 440mm, COZY
18 – 470mm. The maximum wall thickness is 150mm.
The minimum safety distances from wall opening to inflammable materials:
-
from sides of opening 600mm;
-
upward from ceiling of opening 960mm
5