Mistral Mouthpiece Technical Maintenance Manual
PART # DESCRIPTION
Seat Extraction Tool
109437
O-ring Tool
O-ring Tool
944022
Small Blade Screwdriver
Small Blade Screwdriver
N/A
Side Cutters
Side Cutters
N/A
Bottle Brush 2¾" Diameter
Bottle Brush 2¾" Diameter
Bottle Brush 2¾" Diameter
N/A
900016
Service Kit MISTRAL
LUBRICANT/CLEANER
Christo-Lube MCG 111
Oakite #31
White distilled vinegar
Liquid dishwashing detergent
(diluted with warm water)
Table 2: List of Tools and Service Kits
Table 3: Recommended Cleaners and Lubricants
APPLICATION
All o-rings
CAUTION:
Silicone rubber requires no lubrication or preservative treatment.
DO NOT apply grease or spray to silicone rubber parts. Doing so may cause
a chemical breakdown and premature deterioration of the material.
Acid bath for reusable stainless steel and
brass parts.
CAUTION:
Do not use muriatic acid for the cleaning of any parts. Even if
strongly diluted, muriatic acid can harm chrome plating and may leave a
residue that is harmful to o-ring seals and other parts.
Acid bath for reusable stainless steel
and brass parts.
Degreaser for brass and stainless steel
parts; general cleaning solution for plastic
and rubber
APPLICATION
Valve support disassembly
Remove and replace o-rings
Remove and replace clamping bands
Removing Panduit Clamps
Cleaning inside of corrugated hoses
SOURCE
Aqua Lung, PN 820466, or
Lubrication Technologies
310 Morton Street
Jackson, OH 45640
(800) 477-8704
Oakite Products, Inc.
50 Valley Road
Berkeley Heights, NJ 07922
"Household" grade
"Household" grade