When the setpoint plus adjusted alarm value is exceeded, you hear a beep. This value is also adjusted by the
arrow keys. By pressing the "SAVE" key the settings will be saved. As soon as the adjusted setpoint falls below
the adjusted value of the control precision, the unit activates the power socket No. 2 and switches on the
consumer (heating). When the adjusted temperature is exceeded, the unit activates power socket No. 1 and
switches on the consumer (cooling).
Example: The setpoint is set to 25 °C, the cooling and heating control precision at 0.5 °C. As soon as the
temperature rises to 25.5 °C (setpoint + control precision) the cooling unit starts. As soon as the temperature
drops below the
setpoint
If the temperature drops to 24.5 °C
temperature rises more than to the
SET+▲: By pressing this key combination for several seconds, the display can be turned off or on steadily (then
the display shows „On"). However, constant display illumination reduces the service life of the display.
SAVE+▲: Reset. The controller is reset to manufacturer's settings.
▲+▼: By pressing this key combination for several seconds, you get to the switching mode of C (Celsius) and
F (Fahrenheit). Use the arrow keys to change the setting.
By pressing the SAVE-key, the required setting is saved.
A minimum deactivation of 3 minutes prevents heating and cooling work against each other.
The T controller twin has got a rechargeable battery so the programmed data will not be lost in case
of power failure. After starting the unit up, it takes about 24 hours until the battery is charged and
the data remain stored.
For safety reasons, you should control the nominal values, especially after a power failure.
5. Technical Data
Display:
Measurement range:
Resolution:
Loading capacity of contact:
Adjustment range:
Adjustment accuracy:
Power requirements:
Humidity:
6. Warranty conditions
AB Aqua Medic GmbH grants the first-time user a 24-month guarantee from the date of purchase on all material
and manufacturing defects of the device. Incidentally, the consumer has legal rights; these are not limited by
this warranty. This warranty does not cover user serviceable parts, due to normal wear & tear ie: impellers or
drive wheels etc. The original invoice or receipt is required as proof of purchase. During the warranty period,
we will repair the product for free by installing new or renewed parts. This warranty only covers material and
processing faults that occur when used as intended. It does not apply to damage caused by transport, improper
handling, incorrect installation, negligence, interference or repairs made by unauthorized persons. In case of
a fault with the unit during or after the warranty period, please contact your dealer. All further steps
are clarified between the dealer and AB Aqua Medic. All complaints and returns that are not sent to
us via specialist dealers cannot be processed. AB Aqua Medic is not liable for consequential damages
resulting from the use of any of our products.
AB Aqua Medic GmbH - Gewerbepark 24 - 49143 Bissendorf/Germany
5
(here 25 °C) the cooling unit will stop.
(setpoint
- control precision) the heating unit starts. As soon as the
setpoint
(here 25 °C) the heating unit will stop.
0.1 °C
0 up to 50 °C
0.1 °C
1,200 watts at 220 V AC
16 – 40 °C
+/- 0.1 °C
220 – 240 V, 50 Hz
< 85%