Step 9
Guard Rails
Each guard rail section has two T-Locks to secure the guard rail to the Multi-Stage. To install guard
rail:
A. Set the lower lip of the guard rail lock inside the C-Channel along the perimeter of the Multi-
Stage.
B. Swing the guard rail up until the T-Lock is fully seated within the C-Channel of the stage. Press
down on plunger if necessary to seat T-Lock.
C. Tighten the hex nut on each lock to 50 ft-lb.
D. To remove guard rail, loosen hex nut and depress plunger to release T-Lock.
WARNING
Failure to correctly install guard rails could result in serious injury or
death. Verify that each T-Lock is fully seated inside the Multi-Stage,
as shown in Figure B, and guard rail is secure. T-Lock will click
audibly when it is installed.
Section 1012 of the International
Building Code and Section 1008.5.7
of the Uniform Building Code require
the use of guard rails with vertical
posts no greater than 4" apart when
the stage height exceeds 30."