Aqua PRO DV FLO 소유자 매뉴얼 - 페이지 13

{카테고리_이름} Aqua PRO DV FLO에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Aqua PRO DV FLO 20 페이지.

Maintenance (continued)
To avoid dangerous or fatal electrical shock hazard, turn OFF power to the motor before draining the pump.
DANGER:
Disconnect the power at its source, lock out the power, and place a tag on the dedicated GFCI circuit breaker indicating the
power is to remain off.
STORAGE / WINTERIZING
NOTICE Allowing pump to freeze will damage pump and void warranty!
NOTICE Do not use anti-freeze solutions (except propylene glycol) in your pool/spa system. Propylene glycol, or "RV antifreeze", is non-toxic
and will not damage plastic system components; other anti-freeze formulas are highly toxic and may damage plastic components in the
system.
Drain all water from pump and piping when expecting freezing temperatures or when storing pump for a long time (see Draining The
Pump).
Keep motor dry and covered during storage. To avoid condensation/corrosion problems, do not cover pump with plastic.
For outdoor/unprotected installations:
1. Enclose entire system in a weatherproof enclosure.
2. To avoid condensation/corrosion damage, allow ventilation; do not wrap system in plastic.
3. Use a 40% propylene glycol/60% water solution to protect pump to -50°F (-46°C).
STARTUP FOR WINTERIZED EQUIPMENT
1. Remove any temporary weather protection placed around system for shutdown.
2. Follow filter manufacturer's instructions for reactivation of the filter.
3. Inspect all electrical wiring for damage or deterioration over the shutdown period. Have a qualified serviceman repair wiring as needed.
4. Inspect and tighten all watertight connections.
5. Open all valves in suction and return piping.
6. Remove any winterizing plugs in piping system.
7. Drain all antifreeze from system.
8. Close all drain valves and replace all drain plugs in piping system.
9. Prime pump according to instructions in Priming Pump.
To avoid dangerous or fatal electrical shock hazard, turn OFF power to the motor before draining the pump.
DANGER:
Disconnect power at its source, lock out the power, and place a tag on the dedicated GFCI circuit breaker indicating the power is
to remain off.
NOTE: Allowing the pump to freeze will damage the pump and void warranty! Use only non-toxic antifreeze. Do not use automotive antifreeze.
It is highly toxic and may damage plastic components in the system.
13
Please contact 1-877-278-2797 for further assistance.
ECOAQUAPRO.COM