Aqua PRO VIP50PRO 사용 설명서 및 교체 부품 목록
{카테고리_이름} Aqua PRO VIP50PRO에 대한 사용 설명서 및 교체 부품 목록을 온라인으로 검색하거나 PDF를 다운로드하세요. Aqua PRO VIP50PRO 4 페이지. Aquapro systems submersible utility pumps user manual
Instrucciones de funcionamiento y de Instalacion
Para ordenar repuestos en EUA,
llame al teléfono 1-877-278-2797
Sírvase darnos la siguiente información
Escribanos a la siguiente dirección
- Número del modelo
Aqua Pro Systems
(si tiene)
- Número de serie
Attn: Parts Department
101 Production Drive
- Descripción y número de la pieza (tal
Harrison, OH 45030 U.S.A.
como se muestra en la lista de repuestos
No. de
Ref.
Descripción
1
Ensamblaje de la bomba
2
Ensamblaje de la codón eléctrico
3
Ensamblaje de la codo
4
Ensamblaje de la Impulsor
Especificaciones
Requerimientos eléctricos . . . . . . . . . . . . . . . . . .120 voltios, 60 Hz
Motor . . . . . . . . . . . . . . . . . . . .Monofásico, lubricado de por vida
Amperaje máximo del motor . . . . . . .6,2 amperios (1/5 & 1/4 CP)
8,5 amperios (1/2 CP)
Protector térmico . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Automático
Rango de la temperatura del líquido . . . . . . . .4,5-49˚C (40-120˚F)
Posición para el funcionamiento . . . . . . . . . . . . . . . . . . . . .Vertical
Amperaje mínimo del circuito . . . . . . . . . . . . . . . . . . .15 amperios
Peso . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2,9 kg (1/5 & 1/4 CP)
3,3 kg (1/2 CP)
Dimensiones (totales) . . . . . . . . . . . . . . . . .9,5 de altura X 6,13 de
diámetro de la base (24,1 X 15,6 cm)
Garantía limitada
Durante un (1) año a partir de la fecha de compra, Aqua Pro ("Wayne Water Systems") reparará o reemplazará, según lo decida,
para el comprador original, cualquier pieza o piezas de sus Bombas para cloacas o Bombas de agua (el "Producto") que después de un
examen sea(n) hallada(s) por Aqua Pro como defectuosa(s) en su material o mano de obra. Sírvase llamar a Aqua Pro (877-278-2797) para
obtener instrucciones o consulte a su distribuidor. Esté listo para proporcionar el número de modelo cuando ejerza el derecho a esta
garantía. Todos los gastos de transporte de los productos o piezas enviadas para su reparación o reemplazo serán a cargo del comprador.
Esta Garantía Limitada no cubre productos que estén dañados debido a accidentes, abuso, uso indebido, negligencia, instalación
incorrecta, mantenimiento inadecuado, o no hacerlo funcionar según las instrucciones escritas de Aqua Pro.
NO HAY OTRAS GARANTÍAS EXPRESAS. LAS GARANTÍAS IMPLÍCITAS, INCLUYENDO AQUELLAS DE COMERCIABILDAD
E IDONEIDAD PARA UN USO ESPECÍFICO, SON LIMITADAS A UN AÑO A PARTIR DE LA FECHA DE COMPRA. ESTE ES EL ÚNICO
RECURSO Y SE EXCLUYE CUALQUIER RESPONSABILIDAD POR TODO DAÑO DIRECTO O CONSECUENTE O POR CUALQUIER GASTO.
Algunos estados no permiten limitaciones sobre la duración de las garantías implícitas, o no permiten la exclusión ni la limitación de daños
incidentales o consecuentes, por lo tanto es posible que las limitaciones anteriores no se apliquen en su caso. Esta garantía limitada le
proporciona derechos legales específicos, y también puede tener otros derechos que varían de un estado a otro.
En ningún caso, ya sea por incumplimiento del contrato de garantía, incumplimiento (incluyendo negligencia) u otro, Aqua Pro o sus
proveedores serán responsables de ningún daño especial, consecuente, incidental o penal, incluyendo, pero sin limitarse a pérdida de
ganancias, pérdida de uso del producto o cualquier equipo asociado, daños al equipo asociado, costo de capital, costo de productos sustitutos,
instalaciones, de servicio o reemplazo de fuente de energía, costos de inutilidad, o reclamos de clientes del comprador por dichos daños.
Usted DEBE conservar su recibo de compra junto con este formulario. En caso de tener que ejercer un reclamo de garantía, DEBE enviar
una COPIA del recibo de compra junto al material o correspondencia. Sírvase llamar a Aqua Pro (877-278-2797) para obtener
autorizaciones e instrucciones de devolución.
NO ENVÍE POR CORREO ESTE FORMULARIO A AQUA PRO. Utilice este formulario para mantener sus registros.
MODELO NO. _____________________ NO. DE SERIE ___________________________ FECHA DE INSTALACIÓN ______________________
SUJETE SU RECIBO AQUÍ
2
1
3
VIP50PRO
Ctd
57711-001
1
31006-005
1
62002-001
1
62001-001
1
4
Materiales
Envoltura del motor . . . . .Termoplástico reenforzado con vidrio
Voluta . . . . . . . . . . . . . . . . .Termoplástico reenforzado con vidrio
Impulsor . . . . . . . . . . . . . . .Termoplástico reenforzado con vidrio
Eje . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Acero inoxidable 416
Sellos y anillo en O . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Buna N
Cordón eléctrico . . . . . . . . . . . . . . . . . . . . . . . . . . .con 3 terminales
Desagüe
Codo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3,18 cm NPT (1,25 ")
Profundidad de funcionamiento
Profundidad mínima . . . . . . . . . . . . . . . . . . . . . . . . . 0,32 cm (1/8")
8 Sp
Operating Instructions and Replacement Parts List
See Warranty on page 4 for important information about commercial use of this product.
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the
product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could
result in personal injury and/or property damage! Retain instructions for future reference.
General Safety
Description
Information
This portable, submersible utility pump is
designed and intended for non-
1. Know the pump application,
automatic use in water. The units are
limitations, and potential hazards.
equipped with an 8-ft. 3-prong ground-
Read these rules and the instructions
ing-type power cord. The shaded-pole
carefully. Failure to follow them
motor is oil filled and sealed for cooler
could cause serious bodily injury
running and designed to operate under
and/or property damage.
water. The non-clogging impeller design
eliminates debris from stopping the
WARNING
!
pump. The elbow fitting allows
Do not use to pump flammable
convenient discharge through a garden
or explosive fluids such as
hose.
gasoline, fuel oil, kerosene,
IMPORTANT: THIS PUMP IS NOT
etc. Do not use in flammable and/or
SUITABLE FOR AQUATIC LIFE!
explosive atmospheres. Pump should
only be used with liquids compatible
Unpacking
with pump component materials. Failure
Inspect this unit before it is used.
to follow this warning can result in
Occasionally, products are damaged during
personal injury and/or property damage.
shipment. If the pump or components are
2. Make certain that the power source
damaged, return the unit to the place of
(electric motor) conforms to the
purchase for replacement. Failure to do so
requirements of the equipment.
could result in serious injury or death.
DANGER
!
Safety Guidelines
Disconnect power before ser-
This manual contains information that is
vicing. If the power disconnect
very important to know and understand.
is out of sight, lock in the open
This information is provided for SAFETY
position and tag it to prevent unexpected
and to PREVENT EQUIPMENT PROBLEMS.
application of power. Failure to do so
To help recognize this information,
could result in fatal electrical shock!
observe the following symbols.
3. Release all pressure within the system
DANGER
!
before servicing any component.
4. Drain all liquids from the system
Danger indicates an imminently
before servicing.
hazardous situation which, if not avoided,
will result in death or serious injury.
5. Secure the discharge line before
starting the pump. An unsecured
WARNING
!
discharge line will whip, possibly
Warning indicates a potentially
causing personal injury and/or
hazardous situation which, if not avoided,
property damage.
could result in death or serious injury.
6. Check hoses for weak and worn
CAUTION
!
condition before each use, making
certain that all connections are
Caution indicates a potentially hazardous
secure.
situation which, if not avoided, may
7. Periodically inspect the pump and
result in minor or moderate injury.
system components. Perform routine
NOTICE
!
maintenance as required (See Main-
Notice indicates important information,
tenance Section).
that if not followed, may cause damage
to equipment.
REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.
© 2006 Aqua Pro Systems
VIP50PRO
Submersible
Utility Pumps
CAUTION
!
This utility pump is not constructed to
handle laundry discharge or any other
application which may contain caustic
chemicals and/or foreign materials. Pump
damage could occur if the pump is used in
these applications.
8. Provide a means of pressure relief
for pumps whose discharge line can
be shut-off or obstructed.
9. Personal Safety:
a. Wear safety glasses at all times
when working with pumps.
b. Keep work area clean,
uncluttered and properly lighted;
replace all unused tools and
equipment.
c. Keep visitors at a safe distance
from the work area.
10. When wiring an electrically driven
pump such as this, follow all
electrical and safety codes, as well
as the most recent National
Electrical Code (NEC) and the Occu-
pational Safety and Health Act
(OSHA).
11. This equipment is only for use on
120 volt (single-phase) and is
equipped with an approved 3-con-
ductor cord and 3-prong,
grounding-type plug as shown in
Figure 1.
To reduce the risk of electric shock,
the motor must be securely and
adequately grounded. This can be
accomplished by inserting plug
directly into a properly installed and
grounded 3-prong, grounding-type
receptacle (as shown in Figure 1).
TEST
RESET
Figure 1
322700-013 3/06