Aqua Science PURE MAX 소유자 매뉴얼 - 페이지 3
{카테고리_이름} Aqua Science PURE MAX에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Aqua Science PURE MAX 10 페이지. 4 and 5 stage models
A q u a S c i e n c e A Z . c o m
Solutions For Life
IMPORTANT: Before installing this reverse osmosis system, make
certain your water supply complies with the following operating speci-
fications. Failure to do so may reduce the effectiveness of the system
and will void the warranty.
SPECIFICATIONS
Thin Film Composite Membrane:
Feed Water Pressure:
Temperature Range:
TDS (Total Dissolved Solids):
Maximum Hardness †:
Sulfide, Iron and Manganese:‡
Chlorine in Water Supply:
pH Limits:
Turbidity:
†
If the hardness of your water is above 10 gpg (171mg/l), lime scale
will build up rapidly on the membrane. Scale buildup will plug the
membrane and make the system ineffective. We do not recommend
these reverse osmosis systems to be used with water in excess of 10
gpg (171mg/l) hardness.
‡A maximum total level of approximately 0.01 ppm sulfide, iron or
manganese is permissible. Should your water exceed this, see your
local dealer to reduce these substances in your water.
PARTS INCLUDED:
Pre-assembled and leak tested filter system (mounting bracket,
membrane housing, membrane, pre-filter housings, pre-filter cartridges
and post-filter).
* Reverse Osmosis Membrane
* Inlet supply adaptor
* Feed Tubing (1/4-inch)
* Tank valve
C A L L F O R S E R V I C E 4 8 0 - 8 9 4 - 0 7 7 0
TFC
40 to 80 psi
40-100°F
2000 ppm
10 gpg (171 mg/l)
0 ppm <0.1 ppm
Less than 2 ppm
3-9
11 NTU Average
SYSTEM DIMENSIONS
Overall Dimensions:
Weight:
Tank Dimensions
Tank Capacity Max:
Tank Air Pressure Empty
NOTE:
*Storage Tank
•Your water must be within required limits for satisfactory operation. If not,
*Drain saddle
your membrane life may be shortened and your warranty will be voided.
•This reverse osmosis system will not protect against disease-causing
*Tank Tubing (3/8")
bacteria or remove naturally-occurring harmless bacteria.
*Faucet Tubing (3/8")
• Install on cold water line only.
• Do not use wicking or sealer to fitting connections into the cap of the
filter. Plumber tape is recommended.
• Make certain that installation complies with all state and local laws and
regulations.
• The replacement cartridges and reverse osmosis membrane
included with this system have limited service lives. Changes in
taste, odor, and color of the water being filtered indicate that the
cartridge should be replaced (see Replacing the Pre- and Post-Filters,
and Replacing the Membrane).
• After prolonged periods of non-use (such as during a vacation) it is
recommended that the system be flushed for 5 minutes and the tank
drained before it is used.
• A drinking water cartridge may contain carbon fines (very fine black
powder). After installation, flush the system for 5 minutes to remove the
carbon fines before using the water.
• It is recommended that you run the tap at least 20 seconds prior to using
water for drinking or cooking purposes.
• The contaminants or other substances removed or reduced by this water
treatment device are not necessarily present in your water.
14" W x 5 1/2" D x 17" H
17.3 lbs. (dry)
10" Dia. x 14" H
2.8 Gallons
7 to 10psi
3
3