7. VFD DIGITAL SPEED CONTROL

CPE Systems Inc.
|

7.1 Standard Features

• Protection level of IP66 (NEMA 4X) with indoor and outdoor approval; hose-proof,
dust-tight, and approved for use in rough environments.
• First decentral drive in the market with IO-Link Device Interface.
• Sensorless vector control for synchronous motors.
• Intuitive user interface for fast setup and easy navigation by parameter structure.
• Onboard display with built-in diagnostics.
• Micro USB interface for programming and diagnostics.
• Multiple digital and analog inputs for remote control and safety interlocks.
• Compatible with our wireless remote controls, pressure switches and run-dry
protection.
• Full onboard PID programming for interfacing with flow meters, level controls,
pressure sensors, and can/bottle fillers.
• Optional front-mounted potentiometer (speed control knob).
• IO-Link compatible.
Note: Your drive has been programmed with the correct settings for optimal performance.
Do not change the parameter settings without contacting the manufacturer. This will void
the warranty.

7.2 Protection Features

Degree of protection:
• IP66 (EN 60529)
• NEMA type 4X outdoor NEMA 250)
• UL type 4X outdoor (UL 50E)
Insulation resistance:
• Overvoltage category III (EN61800-5-1) - 0 ... 2000 m amsl
• Overvoltage category II (EN61800-5-1) - Over 2000 m amsl
Isolation of control circuits:
• Safe mains isolation via double/reinforced insulation (EN 61800-5-1)
Protective measures against:
• Short circuit
• Earth fault - earth-fault protected depending on operating status
• Overtemperature of motor - PTC or thermal contact
• Overvoltage
• Motor Stalling
Leakage Current: >3.5 mA AC, >10 mA DC (EN 1800-5-1)
Starting Current: ≤ 3 x rated mains current