Thank you for purchasing a CPE Centrifugal Pump. Your pump comes completely set up, wired,
and pre-programmed. Please read this manual front to back, it includes care instructions for
your pump.
This pump was assembled, wired, programmed, and tested before shipping. It should be ready
for use without any modifications or changes required on your part.
1.
Connect inlet (suction) line to the Tri-Clamp fitting on the front of the pump using a
new Tri-Clamp gasket and a heavy duty clamp. The inlet line should be at least the
same diameter as the fitting on the pump. We recommend against clamping a valve or
tee onto the inlet port.
2.
Connect the discharger line to the Tri-clamp fitting on the top of the pump using a
new Tri-clamp gasket and a heavy duty clamp.
3.
Plug power cord into appropriate wall receptacle using the supplied plug. Do not
change the plug or use an adapter, this will void the warranty.
4.
Open valve on inlet line to the pump to allow liquid to flow to the pump.
5.
Open valve on the discharge line if you have one installed.
6.
If so equipped, adjust the potentiometer (speed control knob) on front of the digital
pump controller to the midpoint so the indicator dot on the knob is at the top.
7.
Press the run button
8.
Adjust the speed of the pump by using the up and down arrows
potentiometer (if equipped) to obtain your desired flow.
9.
When you are finished pumping. Stop the pump by pressing the stop button
Do not stop the pump by simply turning down the speed to zero. This will still allow
voltage to the motor and can cause damage and electrical shock.
10. Close both the inlet and discharge valves if equipped.
Note: Do not try to run your centrifugal pump in reverse. It will not operate in reverse; the
forward/reverse button
www.cpesystems.com
briefly to start the pump.
has been disabled.
|
+1 800 668 2268
or the
.
|
3