3. At a location behind the backplate, scribe a mark on the shaft. See figures below.
4. Remove casing clamp, casing, and backplate.
5. Slide the drive collar onto the shaft.
6. Locate drive collar in relation to the scribe mark as shown in dimension A and secure
to the shaft with the set screws. Drive collar location is critical.
Model
"A" Dimension
C114
1 1/32" (2.3 mm)
C216
1 1/32" (2.3 mm)
C218
1 1/32" (2.3 mm)
C328
1 1/32" (2.3 mm)
C4410
1 1/32" (2.3 mm)
7. Install the seal spring, seal cups, seal o-ring, and carbon onto the shaft.
www.cpesystems.com
|
+1 800 668 2268
|
11