Service Manual
351FFOP40N, 351FFOP50N, 351FFOP40L, 351FFOP50L
HIGH LIMIT THERMOSTAT (450°F)
1.
Follow pre-maintenance steps on page 4
2.
Remove 2 hex head screws from side of mounting
bracket, 8mm socket (Fig. 18)
3.
Remove wiring from high limit thermostat, note
locations to move to new high limit thermostat
(Fig. 17)
4.
Pry apart holding tongs on the bracket inside the
fryer pot holding the sensing probe. (Fig. 19)
5.
Remove holding nut for high limit thermostat
capillary wire from underside
of fryer pot with 18mm wrench (Fig. 20)
6.
Remove high limit thermostat capillary
wire and sensing probe from fryer pot
7.
Installation is reverse of removal, ensure sensing
bulb is mounted in tongs before tightening
holding nut
8.
Use thread sealant on holding nut for capillary wire
and ensure no leaks after install
THERMOPILE
1.
Follow pre-maintenance steps on page 4
2.
Remove wires from high limit thermostat that go
to thermopile (Fig. 17)
(White and Red color)
3.
Remove two hex head screws that hold thermopile
bracket in place with an 8mm socket. (Fig. 23)
4.
Remove compression nut from thermopile mount
with a 7mm wrench, do not lose compression nut
(Fig. 22)
5.
Remove thermopile from mount by
pulling down
6.
Slide on compression nut from old thermopile to
new thermopile
7.
Ensure thermopile is fully seated in mounting
bracket before tightening compression nut
8.
Installation is reverse of removal
8
FIG. 17
FIG. 19
FIG. 21
FIG. 23
.
FIG. 18
FIG. 20
FIG. 22