CHECKING & ADJUSTING MAIN BURNERS
The main burners should burn with a steady blue flame and the inner cone of the flame from each port should be about
3/4" long. The flame from each main burner should enter each heat tube without touching the front of the fry pot or the
sides, top, or bottom of each tube.
CHECKING & ADJUSTING PRESSURE REGULATOR
The combination gas valve (includes pressure regulator) is factory set at 4"WC for natural gas and 10"WC for propane
gas. To check the manifold pressure, do the following:
1 . Turn thermostat "OFF" and combination gas valve knob to the "PILOT" setting.
2 . Remove pressure tap plug from burner manifold located directly below the burners in the cabinet.
3 . Install a fitting appropriate to connect a manometer.
4 . Turn combination gas valve to "ON" position and thermostat to "ON." The burners will ignite. Be certain that
sufficient oil is covering the tubes.
5 . With burners on, read manometer.
6 . If the manometer does not read 4"WC for natural gas or 10"WC for propane gas, adjust the regulator.
7 . Remove regulator adjustment screw cap.
8 . With small screwdriver, rotate adjustment screw clockwise to increase or counterclockwise to decrease pressure.
Be sure to adjust with burners "ON."
9 . Turn thermostat "OFF" and set combination gas valve knob to "PILOT" position.
10 . Remove manometer and replace pressure tap plug.
11 . Replace adjustment screw cap.
www.cookingperformancegroup.com
13