CPG 351COHT4M 사용자 설명서 - 페이지 5

{카테고리_이름} CPG 351COHT4M에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. CPG 351COHT4M 14 페이지. Electric countertop convection ovens

User Manual

Installation

These units are designed for commercial use and not for household use .
Installation must conform to all applicable codes . Improper installation will void the
manufacturer's warranty .
Do not obstruct or reduce the air flow rate of the natural ventilation openings on the
oven or the vent located at the rear of the oven .
Discontinue use if power cord or electrical wires are frayed or worn .
This product conforms to UL-197 standards and is required to be installed under a
ventilation hood in accordance with all applicable codes .
Combustiable Clearance Requirements: 20" Sides, 28" Back
Non-Combustiable Clearance Requirements: 2" Sides, 2" Back
Installation Instructions
The place of installation must be indoors, well ventilated, and the ambient temperature must be at least
40 degrees Fahrenheit . The unit is required to have at least 2" of clearance on the sides and back from
non-combustible surfaces, or at least 20" and 28" of clearance on the sides and back, respectfully, from
combustible surfaces . Ensure that all four legs are installed correctly before the operation of this oven .
The unit is required to be installed on a non-combustible surface with 4" legs, or a combustible floor with
a stand . For full-size models, level unit by adjusting the (4) feet which have an adjustment of 1¾" for
accurate leveling .
This product conforms to UL-197 standards and requires it to be
under an exhaust hood . A vertical distance of not less than 48"
shall be provided between the top of the appliance and filters
or any other combustible material . Exhaust installation must
conform to applicable local codes .
Do not obstruct or reduce the air flow rate of the natural
ventilation openings on the oven or the vent located at the rear
of the oven . To ensure proper ventilation and clearance, the
provided spacer is required to be installed .
The spacer must be installed by screwing (2) self-threading
screws on the back of the unit immediately below the cooling
fan.
NOTE:
For Oven Stacking Instructions, please see page 14.
WARNING:
DO NOT OBSTRUCT THE VENT OR COOLING FAN LOCATED AT THE REAR OF
THE OVEN.
www.cookingperformancegroup.com
5