STEP 9:
Flip the unit back over.
STEP 11:
Prior to reattaching the front panel, be
sure to check all fittings for leaks. Then
reattach the front panel for knobs.
Setting Pressure Regulator
Commercial cooking equipment must have a pressure regulator on the incoming service line
for safe and efficient operation, since service pressures may fluctuate on local demand. A
pressure regulator is packed inside every Cooking Performance Group appliance.
NOTICE: FAILURE TO INSTALL THE PRESSURE REGULATOR WILL VOID THE
APPLIANCE WARRANTY.
The regulators supplied along with Cooking Performance Group appliances will have ¾"
inlet/outlet openings and are adjusted at the factory for 5" WC (natural gas) or 10" WC (liquid
propane gas) depending on customer's ordering instructions.
The arrow shown on the bottom of the regulator body shows the gas flow direction, it should
point downstream to the appliance.
5
STEP 10:
Slide the grease trap back into place.
.