CPG 351GUCPG24M 사용자 설명서 - 페이지 6

{카테고리_이름} CPG 351GUCPG24M에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. CPG 351GUCPG24M 15 페이지. Electric countertop griddles

CPG 351GUCPG24M 사용자 설명서
User Manual
Installation
WARNING:
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE, OR MAINTENANCE CAN
CAUSE PROPERTY DAMAGE, INJURY, OR DEATH.
READ THE INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR SERVICING THIS EQUIPMENT.
THESE UNITS ARE SUITABLE FOR INSTALLATION ON NON-COMBUSTIBLE SURFACES ONLY.
DO NOT INSTALL NEAR ANY COMBUSTIBLE SURFACES OR ANY OTHER EQUIPMENT.
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN
THE VICINITY OF THIS OR ANY OTHER EQUIPMENT.
Combustible Clearance Requirements: 8" Sides, 8" Back
LOCATING AND LEVELING THE UNIT
For non-combustible surfaces, do not install the unit closer than 1" from a side wall and/or closer
than 1" from a rear wall.
Your griddle includes four adjustable feet. Ensure that all feet are installed correctly before the
operation of this griddle.
Level unit by adjusting the (4) feet which have an adjustment of 1¾" (43.75mm) for accurate
leveling and perfect line-up with other CPG series units.
EXHAUST CANOPY
This product conforms to UL-197 standards and is required to be installed under a ventilation
hood in accordance with all applicable codes.
A vertical distance of not less than 48" shall be provided between the top of the appliance and
filters or any other combustible material.
Exhaust installation must conform to local codes.
The griddles are designed to operate only for the voltages indicated on the data plate attached to
this griddle, and for alternating current (AC) only.
208/240V service for all models. All units must be hard-wired at installation for 1-phase and
3-phase service. For supply connections use copper wire only, suitable for at least 90°C (194°F).
For 48" griddle, 3-phase parallel supply on 3-phase, dual supply on single phase.
The unit is required to have at least 1" of clearance on the sides and back from non-combustible
surfaces, or at least 8" of clearance on the sides and back from combustible surfaces. Ensure that all
four 4" adjustable legs are installed correctly before the operation of this griddle. The unit is required
to be installed on a non-combustible surface with 4" legs, or a combustible floor with a stand.
6
www.cookingperformancegroup.com
.