CPG CK-HPSU636 사용자 설명서 - 페이지 6
{카테고리_이름} CPG CK-HPSU636에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. CPG CK-HPSU636 11 페이지. Gas step up hot plate
Instructions are for conversion from Natural Gas to Propane (L.P.) on all models. The conversion
should be done before connecting the unit to the gas supply.
Units are shipped from the factory equipped for use with natural gas. Orifices necessary for LP
(propane) are provided in a bag tied to the valve on the front panel.
1. Remove the knobs and front panel. 2 . Uns
1. Remove the trivets from the
top of the appliance .
Note: Unit Number on side
of orifice fittings.
Regulator with brass cap
CONVERSION
Plastic Insert
L.P Position of insert
6
2. Remove the burner from the top
of the gas pipe .
3. Replace the orifice
fittings into the valve.
4. Install the front
panel knobs
5. Before installing the regulator,
unscrew the octagonal cap up, you can
read (NAT) on the plastic insert out of
the cap, flip it over and snap back in
6. Continue with
installation.