CPG CK-HPSU636 사용자 설명서 - 페이지 6

{카테고리_이름} CPG CK-HPSU636에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. CPG CK-HPSU636 11 페이지. Gas step up hot plate

CPG CK-HPSU636 사용자 설명서
Instructions  are  for  conversion  from  Natural  Gas  to  Propane  (L.P.)  on  all  models.  The  conversion 
should be done before connecting the unit to the gas supply. 
Units  are  shipped  from  the  factory  equipped  for  use  with  natural  gas.  Orifices  necessary  for  LP 
(propane) are provided in a bag tied to the valve on the front panel.   
 
1. Remove the knobs and front panel.                                              2 . Uns
1. Remove the trivets from the
top of the appliance . 
 
 
                                               
 
 
 
 
 
 
 
 
Note: Unit Number on side 
 
of orifice fittings. 
 
 
 
 
 
 
 
 
 
 
 
Regulator with brass cap 
 
 
 
 
 
 
 
 
 
CONVERSION 
 
Plastic Insert 
L.P Position of insert 
2.  Remove the burner from the top
of the gas pipe .
3. Replace the orifice 
fittings into the valve. 
      4. Install the front 
panel knobs 
5. Before installing the regulator, 
unscrew the octagonal cap up, you can 
read (NAT) on the plastic insert out of 
the cap, flip it over and snap back in 
6. Continue with 
installation.