ABATEMENT AQUATRAP AT100S 사용 설명서 - 페이지 5

{카테고리_이름} ABATEMENT AQUATRAP AT100S에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. ABATEMENT AQUATRAP AT100S 10 페이지. Lgr portable dehumidifier

WARNING: Pressurized Unit. This equipment is factory-charged with refrigerant R-22 and
is under pressure. Only qualified personnel should attempt repairs to the refrigeration
system. Do not puncture or cut into the refrigeration piping.
WARNING: The unit should never be operated without the compressor terminal cover
properly secured in place on top of the compressor; otherwise, serious injury or death
could result. The cover is required to be securely in place to allow proper operation for
the safety overload, and to act as a shield if the hermetic terminals blow out of the
compressor shell.
AT100S CONTROL PANEL
LCD Display – The scrolling 2-line Liquid Crystal Display (LCD) is the primary communication
device to the user.
ON/OFF Button – Turns the dehumidifier ON by pressing once, and then OFF by pressing
again.
MENU Button – Each press of the button cycles the LCD through its secondary functions in the
following order; Job Hours, Total Hours, then Language Setting. The MENU button is also used
to confirm a change after having navigated to the desired choice using the ENTER button.
Job Hours – Indicates the number of hours that the unit has been operating since it was
last reset to zero. To reset Job Hours to zero, depress the ENTER button.
Total Hours - Indicates the number of hours that the unit has been operating since it
was new.
Language Setting – Each press of the ENTER button cycles through the following
languages on the LCD; ENGLISH, SPANISH, FRENCH. Press MENU to confirm the
choice of language.
ENTER Button – After the MENU button has been pressed, each press of the ENTER button
cycles through the various options that can be changed. Press MENU button to confirm an
entry.
PURGE Button – Forces the pump to drain the pump reservoir of any remaining water.
Pressing the PURGE button initiates a 60 second manual purge. It is especially useful after the
unit has been shut off, but water continues to drain off the evaporator. The unit can then be
given a final manual purge before it is moved.
Normal Operation Indicator - Green LED light that indicates that the unit is "on" and running
normally.
Defrost Indicator – Blue LED light that indicates that the unit is actively defrosting.
Abnormal Operation Indicator – Flashing Red LED light that indicates there is a problem with
the unit, usually accompanied by an audible alarm. Refer to the LED display for any messages
that may be displayed.
5 of 10