Pin Assignment
Pin assignment of HSMC on the RAID board is listed following table-1.
Note:
(*1) HSMC Pin# is pin number defined in HSMC standard, while Samtec Pin# is pin number of
connector specification.
(*2) 150MHz SATA reference clock of CLKIN2P/N is reversed in its polarity due to the board trace,
however, this polarity invertion is no problem because differential clock waveform is symmetrical.
Copyright©2011 Design Gateway Co,.Ltd. All rights reserved.
HSMC
Samtec
HSMC
Pin# (*1)
Pin#
definition
(*1)
1
1 TX_P7
2
2 RX_P7
3
3 TX_N7
4
4 RX_N7
5
7 TX_P6
6
8 RX_P6
7
9 TX_N6
8
10 RX_N6
9
13 TX_P5
10
14 RX_P5
11
15 TX_N5
12
16 RX_N5
13
19 TX_P4
14
20 RX_P4
15
21 TX_N4
16
22 RX_N4
17
25 TX_P3
18
26 RX_P3
19
27 TX_N3
20
28 RX_N3
21
31 TX_P2
22
32 RX_P2
23
33 TX_N2
24
34 RX_N2
25
37 TX_P1
26
38 RX_P1
27
39 TX_N1
28
40 RX_N1
29
43 TX_P0
30
44 RX_P0
31
45 TX_N0
32
46 RX_N0
156
176 CLKIN2P
158
178 CLKIN2N
Table1: HSMC pin assignment of AB12-HSMCRAID board
Signal
RAID Bd connection
Name
destination
HT7P
CN7-S2 (TX Pos)
HR7P
CN7-S6 (RX Pos)
HT7N
CN7-S3 (TX Neg)
HR7N
CN7-S5 (RX Neg)
HT6P
CN6-S2 (TX Pos)
HR6P
CN6-S6 (RX Pos)
HT6N
CN6-S3 (TX Neg)
HR6N
CN6-S5 (RX Neg)
HT5P
CN5-S2 (TX Pos)
HR5P
CN5-S6 (RX Pos)
HT5N
CN5-S3 (TX Neg)
HR5N
CN5-S5 (RX Neg)
HT4P
CN4-S2 (TX Pos)
HR4P
CN4-S6 (RX Pos)
HT4N
CN4-S3 (TX Neg)
HR4N
CN4-S5 (RX Neg)
HT3P
CN3-S2 (TX Pos)
HR3P
CN3-S6 (RX Pos)
HT3N
CN3-S3 (TX Neg)
HR3N
CN3-S5 (RX Neg)
HT2P
CN2-S2 (TX Pos)
HR2P
CN2-S6 (RX Pos)
HT2N
CN2-S3 (TX Neg)
HR2N
CN2-S5 (RX Neg)
HT1P
CN1-S2 (TX Pos)
HR1P
CN1-S6 (RX Pos)
HT1N
CN1-S3 (TX Neg)
HR1N
CN1-S5 (RX Neg)
HT0P
CN0-S2 (TX Pos)
HR0P
CN0-S6 (RX Pos)
HT0N
CN0-S3 (TX Neg)
HR0N
CN0-S5 (RX Neg)
SCKN
(via R1) X1-5 (*2)
SCKP
(via R2) X1-4 (*2)