Abatement Technologies AIRE GUARDIAN AG8000 사용 설명서 - 페이지 9
{카테고리_이름} Abatement Technologies AIRE GUARDIAN AG8000에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Abatement Technologies AIRE GUARDIAN AG8000 20 페이지. Hard-sided mobile containment unit
OPERATING INSTRUCTIONS
BASIC OPERATION
Raising and lowering the header
The AG8000 uses a mechanical system to raise and lower the entire header at a single
operating point which is located on the back of the unit. Since this is a mechanical system,
electricity is not required for this operation. There are two ways to operate this
mechanism: (1) with the hand crank attachment (P/N: HARDWRE161) that is provided
with the unit or (2) with a power drill with clutch (not included). For the power drill option,
a bit for the drill is provided with the unit (3/8" socket adapter with a 5/8" socket). It is
highly recommended that the power drill has a clutch setting to help prevent over
extending the header into the ceiling (use the lowest clutch setting that is able to raise
the header to the ceiling).
Turn hand crank clockwise to raise the
header. Turn hand crank counter-
clockwise to lower the header.
Warning: Do not overextend the header into the ceiling! This may cause damage to
the ceiling and/or the unit. Stop raising the header when the foam seal on the
header touches the ceiling.
Warning: Do not allow the header to collide with any devices or fixtures installed in
the ceiling or walls.
Warning: Be sure the ladder is retracted from the ladder bracket before lowering the
header!
Locking the casters
To lock the casters, push down on the
pedal with work shoe.
Alternatively, a power drill can be used
to quickly and easily raise and lower the
header.
To unlock the casters, push the pedal
towards the wheel with work shoe.
8