8. When testing for a leak at the compressor, move the probe
along the compressor body joints, along the pressure relief
valve and any switches, the all around the compressor shaft
seal area. Shaft seal normally leak during compressor
operation so it may be very difficult to ascertain if a leak exists
because the testing with an electronic leak detector is
performed with the system off. However, any indication from
the LDA1000H in a setting below the 14 g / yr. (0.5 oz / yr.) may
be an indication that a significant leak has been found,
especially if no other leaks have been located.
9. Following any service to the refrigerant system, and any other
service that disturbs the refrigerant system, a leak test of the
repair and of the service ports of the refrigerant system should
be done.
Automotive Chemical Sensitivity Chart
Automotive Chemical
Ford spot and stain remover.
Ford rust penetrant and inhibitor
Ford gasket and trim adhesive
Ford brake parts cleaner
Ford clear silicone rubber
uncured
Motorcraft G-05 anti-freeze
colant heated to 160˚F
Ford pumice/lotion hand cleaner
Motorcraft DOT3 brake fluid
Ford spray carburetor tune-up
cleaner
Ford silicone lubricant
Windshield washer solvent
(methanol base)
Permatex natural blue cleaner
and degreaser
Gunk liquid wrench
Dextron automatic transmission
fluid heated to 160˚F
Mineral engine oil heated to
160˚F
Sensitivity
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
No
No
7
OPERATION
Clears in <
30 seconds
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes