DGF Fabrications N2 설치 및 유지 관리 지침 매뉴얼 - 페이지 2
{카테고리_이름} DGF Fabrications N2에 대한 설치 및 유지 관리 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. DGF Fabrications N2 14 페이지. Gas effect fires (natural gas & lpg) for decorative purposes only
This appliance is fitted with an oxygen depletion sensing system, which automatically shuts off the gas
•
supply to the main burner if the oxygen level in the room is depleted, due to a lack of air, or obstructed
flue that would lead to incomplete combustion of the gas.
In the event that the fire shuts down due to any reason, attempt to restart it. If there is a continuing
•
problem, call in a properly qualified specialist engineer.
There are no user replacement parts in this appliance.
•
A minimum primary air inlet area of 100 square cm. is required for the safe and efficient operation of
•
fires 2N, 3N, 4N, 2L, 3L, & 4L. Failure to observe this instruction is potentially dangerous and will
possibly invalidate the guarantee.
The chimney should be regularly checked to ensure that all the products of the combustion are entering
•
the flue and that there is no build up of soot. If there is, the appliance must be cleaned.
Make sure the appliance is regularly checked and cleaned to ensure that all products of combustion are
•
correctly being expelled by the chimney flue and that there is no build up of soot.
When cold gently remove the simulated coal, pebbles, logs or driftwood one by one and remove soot deposits
with a soft brush.
The vermiculite granules should be level with the top edge of the burner tray. If the vermiculite granules are
replaced use only granules supplied by the manufacturer. A finer granule is not suitable.
Re-lay Aeration guards back over the air circulation holes in the burner tray.
Do not add more simulated coals, pebbles logs or driftwood than supplied.
Ensure that the pilot assembly cover is in place. (Not all decorative fires have them) and re-lay placing larger of
Coal, pebble log and driftwood as first layer to smallest. (see illustrated diagrams for guidance).
Units 1-3 Vulcan St, Edward St Industrial Estate, Darlington. DL1 2UL – Tel: 01325 281304; Fax: 01325 481889
IMPORTANT NOTES
CLEANING THE FIRE
2
DGF Fabrications;