Dell Vostro 5460 소유자 매뉴얼 - 페이지 32

{카테고리_이름} Dell Vostro 5460에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Dell Vostro 5460 39 페이지.

Dell Vostro 5460 소유자 매뉴얼
Battery Charge LED
Discharging when Battery
charge is <=10%

Device Status Lights

Turns on when you turn on the computer and blinks when the computer is in a power management mode.
Turns on when the computer reads or writes data.
Turns on steadily or blinks to indicate battery charge status.

LED Error Codes

Diagnostic LED codes are communicated via the Power Button LED. The Power Button LED blinks the corresponding
LED codes for the corresponding fault condition. Example: For No Memory detected (LED code 2) , The Power Button
LED blinks two times followed by a pause, blinks two times, pause, etc. This pattern continues until the system is
powered off.
Code
Cause and Troubleshooting Steps
1
System board: BIOS ROM failure
System board failure, covers BIOS corruption or ROM error
2
Memory
No memory/RAM detected
3
Chipset Error (North and South Bridge Chipset, DMA/IMR/ Timer Error) , Time-Of-Day Clock test
failure , Gate A20 failure , Super I/O chip failure , Keyboard controller test failure
System board failure
4
RAM Read/Write failure
Memory failure
5
Real-time clock power fail
CMOS battery failure
6
Video BIOS test failure
Video card failure
7
CPU - cache test failure
Processor failure
8
Display
Display failure
32
Off/Hibernate
Off
Standby
Blinking White