Dell PowerEdge 1650 매뉴얼 - 페이지 6

{카테고리_이름} Dell PowerEdge 1650에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Dell PowerEdge 1650 15 페이지. Installing an era/o card
Dell PowerEdge 1650에 대해서도 마찬가지입니다: 사용 설명서 (6 페이지), 정보 업데이트 (44 페이지), 정보 업데이트 (44 페이지), 설치 매뉴얼 (44 페이지), 설치 매뉴얼 (44 페이지), 설치 매뉴얼 (44 페이지), 설치 매뉴얼 (44 페이지), 설치 매뉴얼 (44 페이지), 사용자 설명서 (34 페이지)

Dell PowerEdge 1650 매뉴얼
2
Section
Using WOL after A/C Power Disconnect or
with no Operating System (OS) Installed
(Out-of-Box, or D0uninitialized)
 
Dell's NICs and LOMs can accomplish WOL after a system has been unplugged 
from all A/C power, then returned to A/C power, but not powered on.  This state 
is known as "Out‐Of‐Box WOL" or "D0uninitialized."  This can be useful if 
servers to be installed pass through a central processing point for preparation, 
and then are installed at a remote site. 
 
NICs and LOMs from Dell have WOL disabled by default. Having more than 
one device enabled for WOL in a system can overload the 3.3‐volt auxiliary 
power supply and cause it to malfunction.  Dell strongly recommends that only 
one device be enabled for WOL per system. To enable Out‐of‐Box WOL, create a 
DOS‐bootable floppy and copy the utility, listed in the Tools section above, 
specific to the WOL device to it from the Dell Open Management Server 
Assistant or download it from http://support.dell.com.  
 
Note:  Broadcom B5700 and B5701 based NICs and LOMs do not support WOL 
in this way. 
 
The steps to enabling WOL after A/C power disconnect or with no operating 
system are as follows: 
 
1. Boot the system using the DOS floppy, and run 'IBAUTIL.EXE', 
'UXDIAG.EXE –t ABCD' or 'B57UDIAG.EXE –t ABCD'.  These programs will 
display the physically installed adapters and the status of each card's WOL 
setting.  UXDIAG.EXE is for NetXtreme II devices and B57UDIAG.EXE is for 
NetXtreme I devices. 
 
2. Choose the NIC for WOL, record its MAC address, and note its number on 
the left hand side of the display.   
 
October 2007
a. Enable Intel WOL by typing 'ibautil –nic=X –wole' where X is 
the number of the NIC in the display.   
b. Enable Broadcom NX1 WOL by typing 'b57udiag –w 1 –c X' 
where X is the number of the NIC in the display. 
c.
Enable Broadcom NX2 WOL by typing 'uxdiag –c  X –wol 1' 
where X is the number of the NIC in the display. 
Page 6
Dell Enterprise Product Group