While pulling down on the securing clip, press down on the server module board and slide it
backward out of the enclosure. See Figure 1-9.
F i g u r e 1 - 9 .
Installing the Server Module Board
CAUTION: See your System Information Guide for complete information about
safety precautions, working inside the computer, and protecting against
electrostatic discharge.
Unpack the new server module board.
1
Align the server module board's alignment notches with the enclosure's retaining tabs.
2
See Figure 1-9.
Press down on the server module board and slide it backward until the enclosure
3
retaining tabs are resting on the grounding pads and the securing clip snaps over the
server module board. See Figure 1-9.
Installing the Processor
CAUTION: See your System Information Guide for complete information about
safety precautions, working inside the computer, and protecting against
electrostatic discharge.
1-12
Repl aci ng the S er v er Mo dule Bo ard
R e m o v i n g a n d I n s t a l l i n g t h e S e r v e r M o d u l e B o a r d
grounding pad
alignment notches