Press <Ctrl><M> or <Esc><Ctrl><M> to access the LSI utility.
2
Press <Enter> to access the Adapter Properties Menu.
3
Select Mirroring Properties Menu and press <Enter> to view or modify the mirroring
4
mode.
The two installed SCSI drives are listed with their SCSI IDs:
SCSI ID
Device
0
Fujitsu
1
Fujitsu
Select the primary drive and press the space bar to change the Mirrored Pair field to
5
Primary, and then select the secondary drive and change it to Secondary.
NOTE: Ensure that you select the same SCSI ID that you wrote down during the procedure
in "Manually Deconfiguring Mirrored Mode."
Ensure that the drive fields are set to Primary and Secondary.
6
NOTE: The secondary drive mirrors the primary drive. All other data on the secondary
drive is lost.
Press <Esc> to exit the Mirroring Properties Menu.
7
Select Save changes and exit this menu and then press <Enter>.
8
Press <Esc> to exit the Adapter Properties Menu.
9
Press <Esc> to exit the Main Menu.
10
Select Exit the Configuration Utility and press <Enter>.
11
The server module reboots. During POST, only one hard drive, which is reported as a
virtual disk, is listed on the screen. This indicates that the drives are in mirrored mode.
HBA
ID
LUN
VENDOR PRODUCT
0
0
0
Dell VIRTUAL DISK
0
7
0
LSI Logic 1020/1030
The server module upgrade is complete.
Identifier
MAN3184MP 5507
MAN3184MP 5A01
Mirrored Pair
Status
Primary
Secondary
REV
SYNC
1000
1000c00
320.0
Re plac ing the Se r ve r Mo dule Bo ard
WIDE
CAPACITY
16
18203 MB
16
1-17