Dell PowerEdge 4x00 Series 사용자 설명서 - 페이지 8

{카테고리_이름} Dell PowerEdge 4x00 Series에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Dell PowerEdge 4x00 Series 42 페이지. Rack installation guide
Dell PowerEdge 4x00 Series에 대해서도 마찬가지입니다: 설치 매뉴얼 (28 페이지), 랙 설치 (37 페이지), 랙 설치 (34 페이지), 설치 매뉴얼 (37 페이지)

Dell PowerEdge 4x00 Series 사용자 설명서
6300 and 4x00
1-4
Dell PowerEdge
Figure 1-2. Back of SCSI Backplane Board
1
Cooling fan power cable connector (FAN)
2
Power connector (POWER)
3
System-board data cable connector (PLANAR)
4
Ultra160/m SCSI cable connector (SCSIA)
14. Connect the power cable labeled "HD-B/P" to the connector labeled "POWER" on
the backplane board.
15. Connect the Ultra160/m SCSI cable leading from the connector labeled "SCSI2"
on the system board to the connector labeled "SCSIA" on the backplane board.
16. Slide the system board tray back into the system chassis.
17 . Does the new SCSI backplane board have a different number of drive bays?
Yes. You must change the orientation of the two drive bay keys to match the new
backplane. Go to step 18.
No. Go to step 25.
18. Remove the front bezel.
19. Turn the key in the keylock to lock the drive locking flange (see Figure 1-3).
With the flange in the locked position, you have easier access to the upper drive
bay key screws.
Systems SCSI Backplane Option