Dell PowerEdge C5220 기술 매뉴얼 - 페이지 26
{카테고리_이름} Dell PowerEdge C5220에 대한 기술 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Dell PowerEdge C5220 32 페이지. Poweredge series
Dell PowerEdge C5220에 대해서도 마찬가지입니다: 포트폴리오 매뉴얼 (27 페이지), 테스트 보고서 (13 페이지)
10 Systems management
Systems management for the PowerEdge C5220 is through third-party solutions only. There is no
Dell OpenManage support for server management at this time.
The throughput for the various ports is:
Chassis port upstream is 1GbE
Chassis port downstream to each server's BMC is 10/100
BMC shared port on each server is 10/100
Each PowerEdge C5220 server features an onboard BMC along with the AST2050, which provides
iKVM capability.
Dedicated BMC management is provided with the RJ45 port on the PowerEdge C5000 chassis.
Each sled is accessible.
Each server can be configured to use the dedicated port. That port has a network-like switch in the
back of midplane that can talk to all the sleds BMCs. Each dedicated BMC has its own IP address.
As an alternative, shared management is supported through the bottom RJ45 port (NIC 1) on the
sled itself. The default configuration for this is DHCP, so once it has an IP address, communication
to the server through a browser is established.
Chassis management
There is no PowerEdge C5000 chassis management. Only basic monitoring of fans and power
supplies (for example, power status and fan speed) is available. For more advanced fan and power
management control, please use the server BMC. Monitoring data is read by any of the servers' BMC.
Embedded server management
The PowerEdge C5220 supports BMCs that comply with IPMI v2.0. The PowerEdge C5220 BMC
provides the following features for managing the server remotely or in data center lights-out
environments:
Out-of-band monitoring and control for server management over LAN
Dedicated NIC for remote management through network (through the RJ45 port on the
PowerEdge C5000 chassis)
FRU information report, which includes main board part number, product name, manufacturer
and more
Health status/hardware monitoring report
Sled management, which includes power control, status report, front panel buttons and LED
control
View and clear events log
Event notification by lighting chassis LED indicator and Platform Event Trap (PET)
Platform Event Filtering (PEF) to take selected action for selected events, including nonmaskable
interrupt (NMI)
Watchdog and auto server restart and recovery
Support for multisession and user and alert destination for LAN channel
26
PowerEdge C5220 Technical Guide