Table 1-29. Vendor OEM Commands (NETFUN: 34H, 35H)
Commands
Set LAN Source
Get LAN Source
Chassis Control Command Implementation
Table 1-30. Chassis Control Command (NetFn=00/01, Cmd=02h)
Request Data Byte 1-Bit [3:0]
0h=Power Down
01=Power On
2h=Power Cycle
3h=Hard Reset
4h=Pulse Diagnostic Interrupt
5h=Soft Shutdown
32
Using the Baseboard Management Controller
NetFn
CMD
Request and Response
OEM
13H
REQUEST:
Byte 1 — LAN Source
• 00H – Shared NIC
• 01H – Dedicated NIC
RESPONSE:
Byte 1 — Completion code
Byte 2 — LAN source setting
OEM
14H
REQUEST:
(None)
RESPONSE:
Byte 1 — Completion code
Byte 2 — Current LAN source
• 00H – Shared NIC
• 01H – Dedicated NIC
Description
BMC issues a signal to simulate the ACPI-compliant 4 second power off.
Power on.
Power cycle.
Hard reset.
BMC issues a NMI signal to the system.
BMC triggers a power button signal.