Figure 4: PDU installation.
A quick and easy guide to setting up the Dell PowerEdge C8000
Installing power cables
The steps below assume you have power distribution units (PDU) and rack-
mounted network switches installed in the rack according to the included
documentation. This document does not include installation instructions for these
items, as instructions can vary depending on the type you are installing. Note: Distribute
C8000 power across two power circuits for redundancy.
1. Plug power cables from one side of C8000 chassis into one AC power source and
the other side into a second AC power source. Be sure to run the power cables
down the side of server rack to ensure the cables do not block fans and limit
airflow.
2. Keep the power cables away from Ethernet cables.
3. Do not bend cables more than necessary during installation.
4. Do not place extra lengths of cable in front of cooling intake or exhaust ports.
5. Avoid mounting cables and cabling components in locations that block access to
other equipment within the rack.
6. We recommend labeling power cables for quick identification in the future.
7. If the rack is not full, we recommend allowing space for future cabling.
A Principled Technologies setup guide 6